400-666-5501

Welcome to the official website of Zhejiang Beizhong Technology Co., Ltd!

CN/EN

简介
More

The company has strong R&D capabilities and a wide range of product applications, including online monitoring of gas pollution sources, online monitoring of water pollution sources, process analysis, and process safety.

Product Center

简介
More

Since its establishment, Zhejiang Beizhong Technology Co., Ltd. has made significant progress through the joint efforts of all employees. Today, the company's products have integrated technologies from multiple fields such as optics, microelectronics, software, communication, electromechanical engineering, and analytical chemistry. It is one of the few in the world that simultaneously possesses gas analysis and detection, water quality analysis and detection, and dust analysis.

About Us

简介
More

Since its establishment, the company has continuously explored and innovated in the field of environmental monitoring, with multiple national patents and software copyrights. The company's products have integrated technologies from multiple fields such as optics, microelectronics, software, communication, electromechanical engineering, and analytical chemistry. It is one of the few in the world that simultaneously possesses gas analysis and detection, water quality analysis and detection, and dust analysis. Provide online continuous monitoring of heavy metals in agricultural flue gas and online monitoring solutions for the cement industry.

SOLUTION

简介
More

If you are interested in our company and our products, please feel free to visit our company or our local office for investigation. You can also communicate with us through online consultation, submission of demand forms, sending emails, calling consultation numbers, and other methods!

CONTACT US

Home >> PRODUCT >>Online Monitoring Of Gas Pollution Sources >> GBLA-500 Ammonia Escape Integrated Online Monitoring System
Product Detail

GBLA-500 Ammonia Escape Integrated Online Monitoring System

Collect
  • Product Description

Product Introduction:

The GBLA-500 ammonia escape integrated online monitoring system (NH3, NO, O2) is based on the principles of tunable semiconductor laser absorption spectroscopy (TDLAS) and ultraviolet differential absorption spectroscopy (DOAS) technology. The system consists of three main parts: preprocessing, gas analysis module, and data processing and display. The tested gas undergoes high-temperature sampling probe dust removal, high-temperature transmission through heat tracing pipes, and enters the high-temperature gas analysis module (TDLAS+DO-AS technology) for analysis and measurement. Effectively solved technical problems such as blockage of the flow path caused by low-temperature crystallization of ammonium salts, low measurement accuracy due to the precipitation and dissolution of NH3 in condensed water, and inability to measure due to high dust attenuation in the in-situ system optical path.

Product features:

Single line spectroscopy absorption technology avoids background gas interference, has a low detection limit, and has a small range drift;

Heat tracing above 220 ℃ to avoid ammonium salt crystallization and water absorption;

Compact structure, easy to install, high degree of automation, and low maintenance;

Integrating multiple parameters into the same system while maintaining low measurement costs.

Product application:

Suitable for ammonia escape emission monitoring and process control of SCR or SNCR denitrification devices, including coal-fired power plants, aluminum plants, steel plants, smelters, glass plants, waste to energy plants, cement plants, chemical plants, etc.

Product specifications:

Measurement technology: Tunable Semiconductor Laser Absorption Spectroscopy (TDLAS) technology

Ultraviolet differential absorption spectroscopy (DOAS) technology+zirconia

Zero drift: ≤± 1% F.S./Half year
Range drift: ≤± 1% F.S./Half year

Range of measurement:NH3  :0~10~1000ppm

                 NO:0~50~5000ppm

                 O :0~25%

Analog output: 5 channels of 4-20mA output
Analog input: 3-channel 4-20mA input
Linear error: ≤± 1% F.SDigital communication: RS485/RS232/GPRS
Repeatability: ≤ 1%Detection limit: 0.1ppm (10m optical path)
response time:<90s(T90Purging gas source: (0.4-0.8) MPa nitrogen, purified instrument air


×