400-666-5501

Welcome to the official website of Zhejiang Beizhong Technology Co., Ltd!

CN/EN

简介
More

The company has strong R&D capabilities and a wide range of product applications, including online monitoring of gas pollution sources, online monitoring of water pollution sources, process analysis, and process safety.

Product Center

简介
More

Since its establishment, Zhejiang Beizhong Technology Co., Ltd. has made significant progress through the joint efforts of all employees. Today, the company's products have integrated technologies from multiple fields such as optics, microelectronics, software, communication, electromechanical engineering, and analytical chemistry. It is one of the few in the world that simultaneously possesses gas analysis and detection, water quality analysis and detection, and dust analysis.

About Us

简介
More

Since its establishment, the company has continuously explored and innovated in the field of environmental monitoring, with multiple national patents and software copyrights. The company's products have integrated technologies from multiple fields such as optics, microelectronics, software, communication, electromechanical engineering, and analytical chemistry. It is one of the few in the world that simultaneously possesses gas analysis and detection, water quality analysis and detection, and dust analysis. Provide online continuous monitoring of heavy metals in agricultural flue gas and online monitoring solutions for the cement industry.

SOLUTION

简介
More

If you are interested in our company and our products, please feel free to visit our company or our local office for investigation. You can also communicate with us through online consultation, submission of demand forms, sending emails, calling consultation numbers, and other methods!

CONTACT US

Home >> 新闻资讯 >>公司新闻 >> 气体检测仪常见故障分析及排除
Details

气体检测仪常见故障分析及排除

Time:2020-11-11     Author:北中科技   Read

检测仪使用过程中,气体检测仪难免会发生故障,下面简单举例几种故障的排除方式。当然仪器发生故障首先应确保取样系统处于良好的状态,确保过滤器等气路不被堵塞,没有冷凝液以及气路正确的连接和有正确的流量。然后对检测仪和有关设备进行检查,看有无松动或他们的电源连接或管道连接是否断开等。以下几点故障分析,希望对用户有所帮助:


1、运行过程中显示值卡死在屏幕上,调节电位器零位也不起作用:接插件接触不良或接线端子未接好,检查并排除,必要时需更换接插件;测量电桥有断路、短路或解除不良,查出并排除,若是环室内桥臂有问题,则需要送厂家修理。


2、气体检测仪前面板上加热指示灯长时间不亮:加热板开路,检查加热板及其接线端,排出接触不良,如加热板内部断路,则更换;加热指示灯损坏,更换;控温铂电阻开路,检查接线端是否可靠,如铂电阻内部断路,则更换;与加热板相连的接线端连线松脱,拧紧接线端螺钉。


3、仪表显示不稳:测量电桥工作电流不稳,检查电源及信号放大板上A、B两测试端电压是否稳定在1.2V——1.3V之间的某一值,若不稳,更换N2(3173端可调稳压块);运放电源电压不正常,检查12V电压是否稳定,若不正常,更换损坏元件;测量电桥或有关接线端有接触不良,检查有关元器件有否虚焊及接触不良,没有则排除,必要时更换元器件。